EST3 Installation and Service Manual i Content Important information • v UL 9th edition requirements • vii About this manual • x The EST3 library • xii Related documentation • xiii Chapter 1 System overview • System description • Audio subsystem description • Digital network subsystem • EST2 System Programming Manual Introduction All process control systems may be divided into three fundamental parts: inputs, controls, and outputs. Examples of fire alarm system inputs are smoke detectors, pull stations, and waterflow switches. Typical fire alarm system outputs include bells, strobes, control relays, and emergency audio amplifiers. and for writing rules to govern system operation. EST3 System Operations Manual, P/N This manual provides detailed information on how to operate the system and system components. EST3 International Installation Supplement Manual, P/N This manual provides information specific to systems installed outside the United States and Canada.
EST3X configurations include standalone operation, networking with up to 64 nodes, or integration with an EST3 network com-prising as many as 64 nodes — complete with mass notification capabilities and display of security events. EST3X sets a new standard in front-panel life safety control inter-faces. This manual and the information it contains is intended to be used by persons who have working knowledge of Windows and and for writing rules to govern system operation. EST3 System Operations Manual, P/N This manual provides detailed information on how to operate the system and. EST3 is a modular control platform uniquely designed to meet the needs of applications ranging from standalone single panel fire alarm systems to multi-panel networks with unified fire alarm, security, and Mass Notification functions. Each function uses many of the same components, simplifying system layouts.
EST2 System Operation Manual 5 Installation and operation procedures The typical procedure will appear in the following format: To activate an action: 1. At the 2-LCD, press Activate. 2. Enter a level 1, 2, or 3 password. 3. Press 2 to select Action. 4. Enter the number of the action being activated (nnnn). EST2 System Operations Manual (P/N ) EST2 System Programming Manual (P/N ) EST2 Installation Sheets (P/N ) 2-SDU Online Help EST3 documentation EST3 Installation and Service Manual (P/N ) EST3 System Operations Manual (P/N ) EST3 Installation Sheets (P/N ) EST3 International Supplement Manual (P/N ) 3-SDU Help QuickStart documentation QS1 Technical Reference Manual (P/N ). EST3 System Operation Manual Introduction System operating requirements can be configured based on geographic location and protected premises ownership. In North America, systems can be configured as protected premises (local) systems or as proprietary systems, both in compliance with NFPA
0コメント